Any Manufacturer

OPC UA Device

Also applies to: Siemens S7-1500, Beckhoff TwinCAT, Rockwell L8x, OMRON NX/NJ, B&R, CODESYS 3.5+

60 minutesModerateOPC-UAFull OEE

What You Need

Ethernet cableIncluded in kit
Flowstate edge node or any Node-RED host

Customer provides:

  • OPC UA server endpoint URL
  • Security credentials (if required)
  • Node tree documentation

Physical Connection

  1. 1

    Connect to network

    Ensure the OPC UA server device is on the same network as your Flowstate edge node.

  2. 2

    Find endpoint URL

    The OPC UA server endpoint is typically: opc.tcp://{ip}:4840. Check the device's configuration tool.

Machine Configuration

  1. 1

    Configure Node-RED OPC UA client

    Add an OPC-UA-Client node in Node-RED. Set the endpoint URL. Configure security policy (None for testing, Basic256Sha256 for production).

  2. 2

    Browse node tree

    Use the OPC UA browser to discover available nodes. Subscribe to the nodes you want to monitor (temperatures, speeds, states).

Verification

  1. 1

    Test subscription

    Deploy the flow and verify OPC UA values appear in Node-RED debug. Values should update on change (monitored items).

  2. 2

    Verify in Flowstate

    Check the Operations dashboard for the new device. OPC UA nodes map to Sparkplug B metrics automatically.

Available Metrics (1)

Varies by device — browse OPC UA node tree