Arburg
Allrounder 370 U
Also applies to: Allrounder 270 U, Allrounder 470 U, Allrounder 570 U, Allrounder 720 H
What You Need
Customer provides:
- EUROMAP 77 license (contact Arburg)
- Network access
Physical Connection
- 1
Locate the control panel network port
The Allrounder GESTICA control has an RJ45 Ethernet port on the rear of the control column. Earlier SELOGICA controls have a separate Ethernet module.
- 2
Connect Ethernet to edge node
Run Cat6 from the machine network port to the Flowstate CL260 edge node. Use a static IP in the 10.0.100.x range.
- 3
Verify EUROMAP 77 option
On the GESTICA touchscreen, go to Setup > Communication > EUROMAP 77. Confirm the OPC-UA server is listed. If not present, contact Arburg for licensing.
Machine Configuration
- 1
Enable EUROMAP 77 OPC-UA server
GESTICA: Setup > Communication > EUROMAP 77 > Enable. Note the OPC-UA endpoint URL (format: opc.tcp://<ip>:4840).
- 2
Configure namespace
EUROMAP 77 standardizes the data namespace for injection molding machines. Key nodes: cycle time, clamp force, barrel temperatures, shot count, machine state.
Verification
- 1
Browse OPC-UA namespace
Connect to opc.tcp://<machine-ip>:4840 using UaExpert or Flowstate diagnostics. The EUROMAP 77 namespace should show standardized machine data.
- 2
Verify in Flowstate
Machine appears in dashboard with cycle time, temperatures, clamp force, and shot count within 60 seconds.
Available Metrics (8)
Don't have OPC-UA access?
The universal CT clamp works on any machine — 15 minutes, zero configuration.
CT Clamp Fallback GuideReady to Connect?
Calculate what downtime is costing you, then get started.