Haas

ST-10

Also applies to: ST-10Y, ST-15, ST-20, ST-25, ST-30

30 minutesEasyMTConnectFull OEE

What You Need

Cat6 Ethernet cableIncluded in kit
Flowstate CL260 edge nodeIncluded in kit

Customer provides:

  • Network access

Physical Connection

  1. 1

    Locate the Ethernet port

    On the back of the control cabinet, find the RJ45 port labeled 'NET'.

  2. 2

    Connect Ethernet cable

    Run a Cat6 cable from the machine to the Flowstate edge node.

  3. 3

    Set machine IP

    Settings > Network. Static IP in the 10.0.100.x range.

Machine Configuration

  1. 1

    Enable MDC

    Setting 143 = ON.

Verification

  1. 1

    Ping test

    Ping from edge node. Response <1ms expected.

  2. 2

    MTConnect XML

    Browse to http://<ip>:5000/current — verify spindle, axis, status data.

  3. 3

    Dashboard check

    Machine appears in Flowstate within 60 seconds.

Available Metrics (7)

Execution mode
Spindle speed/load
Feed rate
Program name
Part count
Axis positions
Alarms