Komatsu
H2F Servo Press
Also applies to: H1F, H2F, H4F
What You Need
Customer provides:
- iCON parameter access
- Network access
Physical Connection
- 1
Locate EtherNet/IP module
The H2F has a Komatsu iCON controller with an EtherNet/IP communications module. Locate the RJ45 port on the iCON panel.
- 2
Connect Ethernet
Cat6 from the iCON EtherNet/IP port to the Flowstate edge node.
- 3
Set IP address
On the iCON touchscreen: System > Communications > EtherNet/IP > IP Address. Static IP in 10.0.100.x range.
Machine Configuration
- 1
Enable process monitoring
iCON controller: Setup > Data Output > enable tonnage, stroke position, and cycle data output via EtherNet/IP.
- 2
Configure force curve capture
Enable servo press force-vs-position curve logging. The iCON captures the full curve per stroke for quality verification.
Verification
- 1
EtherNet/IP scan
From the Flowstate edge node, run an EtherNet/IP identity scan. The press should appear as 'Komatsu H2F'.
- 2
Run test stroke
Execute a single stroke. Verify tonnage, position, and cycle time data appear in the Flowstate dashboard.
Available Metrics (8)
Don't have EtherNet/IP access?
The universal CT clamp works on any machine — 15 minutes, zero configuration.
CT Clamp Fallback GuideReady to Connect?