What You Need

Cat6 Ethernet cableIncluded in kit
Flowstate CL260 edge nodeIncluded in kit

Customer provides:

  • iCON parameter access
  • Network access

Physical Connection

  1. 1

    Locate EtherNet/IP module

    The H2F has a Komatsu iCON controller with an EtherNet/IP communications module. Locate the RJ45 port on the iCON panel.

  2. 2

    Connect Ethernet

    Cat6 from the iCON EtherNet/IP port to the Flowstate edge node.

  3. 3

    Set IP address

    On the iCON touchscreen: System > Communications > EtherNet/IP > IP Address. Static IP in 10.0.100.x range.

Machine Configuration

  1. 1

    Enable process monitoring

    iCON controller: Setup > Data Output > enable tonnage, stroke position, and cycle data output via EtherNet/IP.

  2. 2

    Configure force curve capture

    Enable servo press force-vs-position curve logging. The iCON captures the full curve per stroke for quality verification.

Verification

  1. 1

    EtherNet/IP scan

    From the Flowstate edge node, run an EtherNet/IP identity scan. The press should appear as 'Komatsu H2F'.

  2. 2

    Run test stroke

    Execute a single stroke. Verify tonnage, position, and cycle time data appear in the Flowstate dashboard.

Available Metrics (8)

Tonnage (kN)
Stroke position (mm)
Cycle time (seconds)
Die temperature (C)
Strokes per minute (SPM)
Part count
Force curve (kN vs mm)
Servo motor current (A)

Don't have EtherNet/IP access?

The universal CT clamp works on any machine — 15 minutes, zero configuration.

CT Clamp Fallback Guide

Ready to Connect?