Mazak

Quick Turn 250

Also applies to: QT-250, QT-200, QT-300

60 minutesModerateMTConnectFull OEE

What You Need

Mazak SmartBox
Cat6 Ethernet cables (2x) (x2)Included in kit
Flowstate CL260 edge nodeIncluded in kit

Customer provides:

  • Mazak SmartBox (or we can procure)
  • Network access

Physical Connection

  1. 1

    Install Mazak SmartBox

    Connect the SmartBox between the machine's internal network and the plant network. SmartBox translates Mazak proprietary protocol to MTConnect.

    SmartBox is required for older MAZATROL controls. Newer SmoothAi controls have built-in MTConnect.

  2. 2

    Connect to edge node

    Ethernet from SmartBox to Flowstate edge node.

  3. 3

    Configure IP

    Set SmartBox IP in the 10.0.100.x range via its web interface.

Machine Configuration

  1. 1

    Enable data output

    On MAZATROL control: Setup > Communication > Enable MTConnect output.

  2. 2

    Verify SmartBox connection

    SmartBox LED should show solid green when connected to machine.

Verification

  1. 1

    Check MTConnect XML

    Browse to SmartBox IP:5000/current to verify data.

  2. 2

    Dashboard check

    Machine appears in Flowstate.

Available Metrics (6)

Execution mode
Spindle speed/load
Feed rate
Program name
Part count
Alarms

Don't have MTConnect access?

The universal CT clamp works on any machine — 15 minutes, zero configuration.

CT Clamp Fallback Guide

Ready to Connect?