Miller
Auto-Axcess 450
Also applies to: Auto-Axcess 300, Auto-Axcess 675
What You Need
Customer provides:
- Network access
- Insight Centerpoint license (for advanced analytics)
Physical Connection
- 1
Locate network port
The Auto-Axcess 450 has an EtherNet/IP port on the rear (standard on all Auto-Axcess models for robotic integration).
- 2
Connect Ethernet
Cat6 from the rear Ethernet port to the Flowstate edge node.
- 3
Set IP address
Use the front panel: Setup > Network > IP Address. Or configure via Miller Insight Centerpoint software. Static IP in 10.0.100.x range.
Machine Configuration
- 1
Enable Insight data
In the configuration menu, enable weld data output. Miller Insight Centerpoint captures per-weld parameter data.
- 2
Set weld limits
Configure weld parameter limits (voltage/current/WFS windows) so the system flags out-of-spec welds automatically.
Verification
- 1
Test weld verification
Run a test weld. Verify voltage, current, and wire feed speed appear in the edge node data stream.
- 2
Dashboard check
Welder appears in Flowstate with weld parameters, duty cycle, and consumable usage.