Schuler

ServoDirect

Also applies to: MSP 200, MSP 400, MSP 630

60 minutesAdvancedPROFINETFull OEE

What You Need

Cat6 Ethernet cableIncluded in kit
Flowstate CL260 edge nodeIncluded in kit

Customer provides:

  • DigiSim parameter access
  • Network access

Physical Connection

  1. 1

    Locate PROFINET port

    The Schuler DigiSim controller has a PROFINET IO port on the main control cabinet. Some models have dual ports for ring topology.

  2. 2

    Connect Ethernet

    Cat6 from the PROFINET port to the Flowstate edge node.

  3. 3

    Set IP / device name

    Use Siemens PRONETA or the Schuler HMI to assign a device name and IP address to the PROFINET device.

Machine Configuration

  1. 1

    Enable DigiSim data output

    On the Schuler HMI: Settings > DigiSim > Data Export > enable press monitoring output. Select parameters: force, position, SPM, energy.

  2. 2

    Configure PROFINET cyclic data

    Set the PROFINET IO module to output process data: slide position, press force, SPM, and energy per stroke. Typical cycle time: 4ms.

Verification

  1. 1

    PROFINET DCP scan

    Run a DCP scan from the edge node. The press should appear with its configured device name.

  2. 2

    Run test cycle

    Execute a press cycle and verify force curve, slide position, and energy data appear in Flowstate.

Available Metrics (8)

Press force (kN)
Slide position (mm)
Strokes per minute (SPM)
Energy per stroke (kJ)
Die cushion force (kN)
Servo motor temperature (C)
Part count
Force curve profile